Abstract

Abstract A model has been developed for hot-gas filtration by candle filters, which includes incomplete removal of the filter cakes by the cleaning backpulses of compressed air. Operational data from the filtration system of the Integrated Gasification and Cleanup Facility at the Federal Energy Technology Center were analyzed with the model and used to estimate the cake permeability, thickness of cake left on the filter after each backpulse, and total cake thickness vs. time. The statistical R 2 for the fit of the incomplete-cleaning model was 0.93, compared to the R 2 = 0.78 previously obtained for a fit of the ‘ideal filtration’ model to the same data set.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.