In this paper, a novel N+2 power converter is introduced and be applied to a six-phase switched reluctance motor (SRM) drive system. Compared with six-phase asymmetric half bridge (AHB) converter, the number of power devices required by this N+2 converter is greatly reduced, while the independence and controllability of each phase can be ensured. However, in N+2 converters, the two midpoint switches are also important components and working at much higher switching frequency than phase switches. The value of the midpoint current directly affects the heating problem of these midpoint switches then affects the reliability of the N+2 converter. Hence, different operate modes of multi-phase excitation state of N+2 converter are enumerated to obtain the relation between the midpoint current and phase currents. Then the characteristics of the midpoint current under different control parameters were obtained through MATLAB-Simulink, and the parameter optimization rules for reducing the amplitude of midpoint current are summarized. In addition, the characteristics of midpoint current in several typical fault states are also summarized. Finally, the simulation results are verified by experiments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.