Changes in the properties of a FiTreM track membrane filter with a pore diameter of 0.45 μm during water filtration and changes in filtration rates during continuous water filtration were studied. The decrease in filtration rates during the passage of distilled water through a track membrane filter is explained by the compaction of the filter and the change in membrane permeability due to the accumulation of a negative charge on the pore surface due to the dissociation of COOH groups.