Abstract

An experimental setup was assembled for precision measuring of soiled pipe nipple thread parameters. The experimental setup error was evaluated in accordance with ISO 10360-8 standard. Law of distribution was defined for thread pitch and height values measured by setup. Special composite material casts were used to verify laser scanner accuracy during thread pitch and height measurement. Casts from the thread surface were measured using a precise optical microscope to find pitch and height values with the accuracy ten times greater, than the accuracy of the assembled experimental setup. Fifteen independent measurements were made to evaluate the relative error of the pitch and height values. Comparison of the microscope and setup measurement results was made to evaluate the absolute error of the pitch and height values. The possibility of achieving by 2D laser triangulation scanner of regulatory requirements to the measurement accuracy of API 5CT standard for the soiled threaded pipe was confirmed experimentally.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.