Abstract

NiCoCrAlY coating was deposited on Superfer 800H superalloy with cold spray process to reduce the degradation rate of substrate superalloy in actual medical waste incineration environment. Erosion–corrosion performance of uncoated and cold sprayed superalloy was evaluated in the secondary chamber of medical waste incinerator. The degradation rate of the specimens was assessed by measuring the thickness loss of the specimen after cyclic exposure for 1000h in medical waste incineration environment. Average degradation rate for uncoated and cold sprayed superalloy was found to be 157.95mpy and 36.56mpy respectively. The better performance of cold spray coated specimen might be attributed to the formation of protective Al2O3 scale at the top of surface and dense structure of the deposit coating.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.