In this work we present a model of signal temporal development in ionization chambers and we use it to determine ionic mobilities and relative densities of charge carriers in non-ultrapure liquid isooctane using a liquid-filled ionization chamber dosimeter. The detector has been irradiated with a low dose rate, short pulsed photon beam generated with a medical LINAC. Ionic mobilities have been obtained by studying the temporal development of the readout signal and fitting it to a model for low dose rate beams where recombination is negligible. The best fit has been obtained for 3 ionic species with mobilities k1 = (2.22±0.22) × 10−8, k2 = (3.37±0.43) × 10−8, k3 = (19.69±2.59) × 10−8 m2 V−1 s−1 and relative densities n1 = 0.5 (n1 is not a fitting parameter), n2 = 0.23±0.03 and n3 = 0.27±0.03.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.