Abstract

Ultrasound imaging is a non-invasive technique to assess organ function. Its potential application in rodents to evaluate respiratory function remains poorly investigated. We aimed to assess and validate ultrasound technique in rats to analyze inspiratory and expiratory muscles. We measured respiratory parameters to provide normal eupneic values. Histological studies and plethysmography were used to validate the technique and assess the physiological implications. A linear relationship was observed between ultrasound and histological data for diaphragm and rectus abdominis (RA) measurement. The tidal volume was significantly correlated with the right + left RA area (r = 0.76, p < 0.001), and the rapid shallow breathing index was significantly and inversely correlated with the right + left RA area (r=-0.53, p < 0.05). In the supine position, the right and left diaphragm expiratory thickness were not associated with tidal volume obtained in the physiological position. Ultrasound imaging is highly accurate and reproducible to assess and follow up diaphragm and RA structure and function in rats.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.