Abstract

The inability to separate fluoride, phosphate and sulfate by electrostatic ion chromatography (EIC) was overcome by using an ODS silica column coated with mixed zwitterionic-cationic surfactants as the stationary phase. The best results were obtained using the zwitterionic surfactant, 3-(N,N-dimethylmyristylammonium)-propanesulfonate (C19H41NO3S), and the cationic surfactant, myristyltrimethylammonium, CH3(CH2)13N+(CH3)3, in a 10:1 molar ratio in the column coating solution. With a dilute solution of sodium tetraborate as the eluent the model analyte anions were completely separated in the following elution order: F, HPO42-, SO42-, Cl-, NO2-, Br-, NO3-. The very early elution of phosphate and sulfate is most unusual and is unique to this system. Detection limits better than 1.1 x 10(-4) mM and linear calibration plots up to 7.0 mM were obtained with a suppressed conductivity system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.