Abstract

In view of the main problems faced by power plants, many scholars in China have focused on the problem of distribution adjustment of secondary air. This paper also conducted research on the adjustment of secondary air distribution. In this paper, a 200MW four-corner tangential boiler of a power plant is taken as the research object, and the overall size of the boiler and the modification of the damper are clarified. The boiler is tested under different loads and different working conditions. Through the inverse balance calculation of boiler thermal efficiency on the SCR inlet NOX analysis, the combination of numerical simulation and test method provides an important reference for the four-corner tangential boiler optimization and variable load operation in the future. At present, the domestic research on the numerical simulation of boiler combustion is mainly to change the different secondary air distribution methods. In this paper, the analysis of the effects of different number of tertiary air nozzles on the combustion of boilers under different loads is studied under the condition of equal secondary air.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call