Abstract

A new method was developed for effective separation and simultaneous determination of estrogens, gestagens, and androgens, including estrone, 17β-estradiol, testosterone, progesterone, and estriol, in infant formula. The samples were enzymatically digested with β-glucuronidase/arylsulfatase prior to microwave-assisted extraction. After the extract was cleaned up by gel permeation chromatography the hormones were derivatived with 50 μL BSTFA containing 1 % TMCS. The derivatived hormones were measured with GC–MS/MS using electron impact ionization source in the positive multi-reaction monitoring mode. The calibration curves showed good linearity with correlation coefficient (r) of >0.999. The limit of quantification of five hormones ranged from 0.094 to 0.265 μg kg−1, which is below the minimum required performance limits established by the European Community. The intra- and inter-day precision (as RSD) for six determinations of five analytes at 40 μg kg−1 spiked level was in range of 3.4–5.4 % and 3.5–6.8 %, respectively. The recovery of five analytes was obtained to be 84.5–104 %, with relative standard deviations (RSD, n = 6) of 1.7–5.5 %. This method has been successfully used for the qualitatively and quantitatively determination of estrone, 17β-estradiol, testosterone, progesterone, and estriol in infant formula.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.