Abstract

Ultra-hydrophilic per- and polyfluorinated sulfonates (PFSA) are increasingly scrutinized in recent years due to their ubiquitous occurrence, persistence, and aqueous mobility in the environment, yet analysis remains a challenge. This study developed methods for the analysis of trifluoromethanesulfonate, perfluorobutanesulfonate, 10-camphorsulfonate, and a di-fluorinated sulfonate utilizing mixed-mode liquid chromatography, where all analytes were adequately retained and separated. Chromatography and electrospray ionization parameters were optimized; instrumental limits of quantification for the anionic target analytes were in the range of 4.3 - 16.1 ng L−1. Solid phase extraction (SPE) methods were developed using Oasis WAX cartridges; SPE recoveries for the analytes ranged from 86% to 125%. Salinity and total organic carbon both impaired the SPE performance to different extents, depending on the respective analyte. Utilizing widely accessible instrumentation and materials, this is a single method to simultaneously analyze conceivably the most hydrophilic PFAS chemical, i.e., trifluoromethanesulfonate, and moderately hydrophobic PFSAs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call