Abstract
With the wide application of hydrogen, the research related to 70 MPa pressure level hydrogen storage tank is very important. This paper takes the 70 MPa hydrogen storage tank in the hydrogen refueling station as the research object, and analyses the diffusion characteristics of hydrogen after leakage from the tank under different wind conditions by FLUENT. Studies find that after hydrogen ejects to the obstacle by the effect of high-pressure, it transforms to be dominated by the simple diffusion and the wind condition. The ambient wind helps to reduce the volume fraction of hydrogen. This paper proposes risk mitigation measures based on the distribution of the flammable clouds — installing nitrogen outlets and reducing the height of the enclosure. The volume of flammable clouds is reduced from about 2.72 m3 to less than 0.045 m3 after adding measures, which proves the feasibility of the measures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.