Abstract
In this article heat losses of absorber tubes of parabolic trough collectors for the collector field of 250 kW Shiraz (Iran) solar thermal power plant is evaluated for various conditions. For analysis, both experimental measurements and numerical modeling are made to find the impact of failure of heat collecting tubes. The amount of heat losses are compared numerically for 3 different types of tubes; vacuum, lost vacuum (air) and broken glass (bare) tube. The experimental measured data are used to validate the numerical simulation. For temperature measurements around the glass tube and absorber tube an infrared thermograph (IR) camera is used. Thermal images are calibrated with measuring some local temperatures. For theoretical simulation a commercial code for thermal analysis of parabolic collectors are used. An absorber tube with vacuum reduces significantly the heat losses in comparison with broken tube or tube without vacuum. During power plant operation poor isolation or any glass tube failure should be avoided for any solar thermal power plants.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.