Abstract
A simple and rapid method was developed for the analysis of total germanium (Ge), inorganic Ge (GeO2) and organic Ge (β-carboxyethyl germanium oxide ; CE-Ge) in Ge-containing health beverages. In order to determine total Ge, the sample was digested with HNO3. Ge in the sample was changed to inorganic Ge, and extracted with CCl4 as chloride. The amount of Ge was determined by polarized Zeeman atomic absorption spectrometry with a nitrous oxide-acetylene flame by using the discrete nebulization technique (FZAAS). On the other hand, inorganic Ge and organic Ge in the sample were separated by organic solvent extraction and determined by FZAAS without acid digestion. Recoveries of Ge from juice fortified at the level of 25-250 μg Ge/g were more than 92%. The calibration graph was linear between 0.25 and 20μg Ge. The proposed method was recommended for the determination of Ge and differentiation of inorganic Ge and organic Ge in Ge-containing health beverages.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.