Abstract

In this paper, the gas turbine blades middle double swirl cooling structure under diverse number of nozzles N are constructed to explore the heat transfer and flow behavior. The k-ω turbulence model are applied and the inlet coolant Reynolds number is 12500. The N vary by 4 to 11 and two cases are investigated. For case 1, the cross-sectional area of each nozzle is 6 mm2 for all structures. For case 2, the cross-sectional area of total nozzles stays the constant at 42mm2 when the N is varied. Results show that, in case 1, when the N increases, the area of the high heat exchange zone decreases but the distribution is more uniform. Moreover, the thermal performance factor ξ gets larger, but the average Nusselt number Nua decreases significantly. In case 2, when the N increases, the ratio of inclination to nozzle length increases for the jet near the outlet, Nua is almost constant but the heat transfer uniformity is improved. The best ξ is obtained when the N is 8. For case 1, as the N is increased, the Nua decreases significantly. Therefore, heat transfer and ξ should be considered by case 2 to select the optimum N.