Abstract

This paper makes finite element analysis of fire resistance under different connections for portal steel frames. Fire protection not apply on the secondary beam, there are two ways of girder-column's connection to calculate: beam connection, and pin connection. The results of the analysis indicate that the mechanical behavior of steel frames in fire conditions is dominated by the effects of thermal loading, thermal expansion and thermal gradient. The overall deformation of pin connection is larger than it of beam connection, and the stress suffered by beam structure is bigger than pin structure. When the overall beam steel frames' connection is taken by local pin connection, the stress of structure will reduce, helping to ensure strength and stability of steel structures. The deformation of the girder can be reduced when the beam connection is taken place by pin connection. The conclusion provides a reference for structural engineers on fire resistant design of steel frame.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.