Abstract
This paper presents a new method of analysing the error of a sampled-data velocity stabilising system with a wide range of pulse width modulation. The analysis is based on multi-channel model obtained as a result of approximation of pulse-modulated signal at the output of a PWM converter. Approximation of piecewise-linear modulation characteristics of each channel has been obtained as a series expansion of Hermite polynomials where the expansion comprises two polynomials of the first and third orders. The transfer function of every channel and a closed-loop system has been obtained using multidimensional Z-transform. The analytical expression of an error under impact of a step input has been derived using a transfer function of the closed-loop system. A dc electric drive has been used as an example of high accuracy sample-data stabilising system to verify and demonstrate the proposed method.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.