Abstract

The purpose of this paper is to study and analyse the energy that is used by the various motors of a crane of the Rubber Tyred Gantry type. For this reason a single Rubber Tyred Gantry (RTG) crane has been instrumented at port of Felixstowe and data has been collected during normal operation for eight days. This data has been analysed in terms of active and idle modes and also in terms of energy usage by the various motors. From this analysis it is possible to determine that on average about half of the energy consumed is potentially recoverable. It is also estimated that the recovery of this proportion of energy could lead to savings of 32,600 L of fuel and 8100 tonnes of CO2 per year at Port of Felixstowe.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.