Abstract

Since many Cascaded H-bridge multilevel (CHBML) inverters that are applied to drive high voltage machines can't transmit electric energy reversely, the electric energy transmitted from the machines may damage the inverters. This paper presents a transfer function to analyze the electromagnetic torque, when the load torque changes suddenly. Based on the achievements, the electric energy that flows between the machine and the inverter can be calculated. And then, a method is proposed to prevent the reversion of the direction of energy flow. Furthermore, the transfer function can be used to guide the design of the control system of induction machine. Simulation results verify the transfer function and the presented method.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.