Abstract

In atomic force microscope (AFM) as a powerful device for scanning the samples, a cantilever is used to sense the variations of its dynamic characteristics due to the tip–sample interaction. Theoretical models that can accurately simulate the surface-coupled dynamics of the cantilever are necessary for quantifiable and qualitative explanation and understanding of measured results. A good understanding of the dynamics of AFM cantilevers vibrating in liquid is needed for the interpretation of scanning images, selection of AFM operating conditions and evaluation of sample’s mechanical properties. In this paper, the amplitude of frequency response functions (FRF) of vertical and rotational movements for a V-shaped atomic force microscope beam immersed in various surroundings has been surveyed for the first time. For rising the precision of theoretical model, we have considered all needful details for the beam and sample. The amplitude of FRF of vertical and rotational movements and resonant frequency of beam have been surveyed by supposing cantilever thickness, breadth and length, the angle between cantilever and sample surface, tip height and normal and lateral tip–sample interaction force. In this study, carbon tetrachloride (CCL4), methanol, acetone, water and air have been considered as surroundings. The results show that an increase in the tip–sample interaction force considerably raises the amount of resonant frequency. By increasing the liquid viscosity, the amplitude of FRF for vertical and rotational movements and resonant frequency reduce. Moreover, the amplitude of FRF of vertical and rotational movements is reduced by raising the rectangular and tapered parts lengths, but increased by raising the rectangular part breadth and cantilever thickness. The resonant frequency goes down by increasing the rectangular and tapered parts lengths and rectangular part breadth, but increases by rising the cantilever thickness. In this paper, we have tried to model the realistic dynamic behavior of V-shaped AFM beam in contact and tapping modes with the most accuracy. Results show good agreement. Based on the experimental results, the present theoretical model can forestall better the realistic behavior of tapping mode than the contact mode for V-shaped AFM cantilever. Based on the complexity of the V-shaped AFM cantilever, this study has been done for the first time in both of the contact and tapping modes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.