Abstract

Dendrites were observed in the failure of semiconductor sensor devices. EDX analysis showed that the dendrites grown from bare sensor dice consisted of tin metal. The tin dendrites exhibited massive and dense branches. Dendrites grown from mechanically decapped parts consisted of silver. The silver dendrites exhibited delicate, lace-like structure. Binary and grey scale images of dendrites were analyzed for fractal dimension number and branch density. The tin dendrites had a higher, statistically significant branch density number than silver, due to tin’s more intricate branching pattern. Fractal numbers can be used to differentiate between tin and silver dendrites, even in the absence of EDX analysis equipment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.