Abstract

Climate change has a potential impact on the number of hot and torrid days in the summer period. Due to the occupants’ comfort needs, and because of the high heat loads during the summer period, in several European countries, the energy used for air conditioning in buildings increased. With multiple environmental monitoring systems (Testo Saveris) in two similar offices, having west and east orientation of glazing, 1920 data (internal air, mean radiant temperature) related to operative temperature were collected in order to show the differences between heat loads of rooms with similar geometry in the same building. Data were measured in a 15 min interval. The diffuse and direct solar radiation had been determined for the horizontal and vertical surfaces, using the measured hourly global radiation (Debrecen, Hungary) data for the analyzed days (summer, hot, and torrid days). The local climatic results were compared with other climatic days used in different national standards. The daily energy need for cooling for different building comfort categories was also determined in the case of the representative days. The maximum daily energy need for cooling can be even 2.3 times higher for east orientation in comparison to the west orientation of the facades.

Highlights

  • Climate change has a potential impact on the number of hot and torrid days in the summer period

  • The daily energy need for cooling for different building comfort categories was determined in the case of the representative days

  • Bazazzadeh et al, in their research, conclude that the cooling load will increase by 135% by 2080 in Poland [12]

Read more

Summary

Introduction

Climate change has a potential impact on the number of hot and torrid days in the summer period. Due to the occupants’ comfort needs, and because of the high heat loads during the summer period, in several European countries, the energy used for air conditioning in buildings increased. With multiple environmental monitoring systems (Testo Saveris) in two similar offices, having west and east orientation of glazing, 1920 data (internal air, mean radiant temperature) related to operative temperature were collected in order to show the differences between heat loads of rooms with similar geometry in the same building. The diffuse and direct solar radiation had been determined for the horizontal and vertical surfaces, using the measured hourly global radiation (Debrecen, Hungary) data for the analyzed days (summer, hot, and torrid days). The daily energy need for cooling for different building comfort categories was determined in the case of the representative days. Most of the energy is used by the building sector, mainly for the daily operation of modern buildings, intelligent buildings for offices, and for public use [4]

Objectives
Methods
Findings
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.