Abstract

When presenting a stereo sound through bilateral stimulation by two bone conduction transducers (BTs), part of the sound at the left side leaks to the right side, and vice versa. The sound transmitted to the contralateral cochlea becomes cross-talk, which can affect space perception. The negative effects of the cross-talk can be mitigated by a cross-talk cancellation system (CCS). Here, a CCS is designed from individual bone conduction (BC) transfer functions using a fast deconvolution algorithm. The BC response functions (BCRFs) from the stimulation positions to the cochleae were obtained by measurements of BC evoked otoacoustic emissions (OAEs) of 10 participants. The BCRFs of the 10 participants showed that the interaural isolation was low. In 5 of the participants, a cross-talk cancellation experiment was carried out based on the individualized BCRFs. Simulations showed that the CCS gave a channel separation (CS) of more than 50 dB in the 1–3 kHz range with appropriately chosen parameter values. Moreover, a localization test showed that the BC localization accuracy improved using the CCS where a 2–4.5 kHz narrowband noise gave better localization performance than a broadband 0.4–10 kHz noise. The results indicate that using a CCS with bilateral BC stimulation can improve interaural separation and thereby improve spatial hearing by bilateral BC.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call