Abstract

Aiming at the problem of the corona discharge trigger electric filed threshold at different shapes of a metal tip, through the theoretical analysis of the electric field distribution near the surface of the conical tip and the ellipsoidal tip, and the laboratory simulation experiment, reached the following conclusion. The relationship between the value of corona current amplitude, the frequency and the tip’s radius of curvature is obtained; the corona discharge electric field threshold is relatively fixed and between 6.9382 kV/cm and 8.2824 kV/cm. The above relationship has a certain reference value in practical application and computer simulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.