Abstract

To estimate the operational characteristics of duel cell power plants, the authors developed a dynamic simulator and analyzed the operating characteristics. In the simulations, attention is given to the pressure difference between the cathode and anode of the fuel cell and the system base pressure. The former is important for safe operation of the fuel cell and the latter is important for safe operation of the reformer. For load following and shut-down modes of the 1 MW plant studied, calculation results were compared with actual test results and agree fairly well.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.