Abstract
Hydrogen-deuterium exchange (HDX) is a technique that measures the exchange of protein hydrogens for deuteriums in a D2O-containing buffer, providing readout of the structural dynamics. Histidine hydrogen-deuterium exchange mass spectrometry (His-HDX-MS) is a variation of this technique that measures the slow HDX of imidazole C2 hydrogens of histidines. This measurement, when accompanied by pH titration, provides both pK as and half-lives (t 1/2) of the HDX reaction for individual histidine residues in proteins. The pK a and t 1/2 values indicate the electrostatic environment and the degree of side-chain solvent accessibility of the histidine residues, respectively. Herein we describe an experimental protocol to characterize rhodopsin by His-HDX-MS. This technique can be used to monitor different states of rhodopsin and might be useful for monitoring longtime scale events in other GPCRs.