Abstract

Among the numerous organochlorines (OCs) applied in the French West Indies (FWI), chlordecone (hydrated form C10Cl10O2H2; CLD) still causes major environmental pollution nowadays. A recent report revealed the unexpected presence in FWI environment of transformation products (TPs) of CLD not routinely monitored due to a lack of commercial standards. Here, we present a method for surface waters and groundwaters to analyze CLD, its main TPs (hydroCLDs, chlordecol (CLDOH), 10-monohydroCLDOH and polychloroindenes) and other OCs. We developed an SPME-GC-SIM/MS method with a PDMS-DVB fiber. Since CLDOH-d commonly used as internal standard (IS) proved unsuitable, we synthesized several IS candidates, and finally identified 10-monohydro-5-methyl-chlordecol as a satisfactory IS for CLDOH and 10-monohydroCLDOH avoiding the use of 13C-labelled analogue. LODs for CLD and its TPs varied from 0.3 to 10 ng/L, equal to or below LODs of the two laboratories, BRGM (the French geological survey) and LDA26 (one of the French Departmental Analytical Laboratories), requested in FWI pollution monitoring that used liquid-liquid extractions and advanced facilities (LLE-GC‐MS/MS and LLE-LC-MS/MS methods, respectively). Then, we extended the multi-residue method to 30 OCs (CLD and its TPs, mirex, β-HCH, lindane, dieldrin, aldrin, HCB, hexachlorobutadiene, TCE, PCE) and applied it to 30 surface and ground waters from FWI. While CLD, 8- and 10-monohydroCLD, CLDOH, 10-monohydroCLDOH, dieldrin, and β-HCH were detected and quantified, pentachloroindene, another CLD TP, was sporadically found in trace levels. A comparison with BRGM and LDA26 confirmed the interest of the SPME method. Results suggested an underestimation of CLDOH and an overestimation of high CLD concentrations with one of the currently used routine protocol. In light of these findings, previous temporal monitoring of environmental waters in FWI were re-examined and revealed some atypical values, which may indeed be due to analytical bias. These discrepancies call for intensified efforts to reliably quantify CLD and its TPs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.