Abstract
The paper sums up the results of a complex analysis, using metallographic, microfractograpic and other methods, with the aim of establishing the cause of fractures appearing in bolts of a terminal board. The analysis has shown unambiguously that the bolt failure was a synergic effect of inadequately performed heat treatment and hydrogenation that occurred in course of surface treatment via pickling and subsequent zinc plating.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.