Abstract

Illicitly produced heroin is commonly cut with carbohydrates to increase bulk. The analysis of these solutes is important for legal and intelligence purposes. A capillary electrophoresis (CE) method was developed for the qualitative analysis of dextrose, lactose, sucrose, inositol, and mannitol in heroin exhibits. For this method, a 64 cm (55.5 cm to detector window) by 50 mum capillary was used with the Agilent Basic Anion Buffer modified to pH 12.1. This separation was performed at 25 degrees C with a voltage of 20 kV and indirect detection with 2,6-pyridinedicarboxylic acid as the visualization reagent. The methodology is also applicable for the screening of inorganic and organic anions using indirect detection, and acidic adulterants using direct detection. For a run time of 13 min, the relative standard deviation (n = 6) of the methodology was better than 0.36% for migration times and less than 2.6% for corrected peak areas. For the analysis of carbohydrates and acidic adulterants in seized heroin, excellent agreement was obtained between CE and nuclear magnetic resonance spectroscopy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.