A fluid dynamics in a micro channel for analytical chemistry and different aspects of this type of flow for specific application has remained a long-acting problem in the last two decades considering its numerus applications in various fields, thus, Surface tension and wall adhesive forces are often used to transport fluid through micro channels in Micro Electromechanical system devices or to measure the transport and position of small amounts of fluid using micropipettes. Here we took the advantages of wall adhesion and surface tension at the air/fluid interface, fluid rises through the channel and study also calculate the velocity, pressure and shape and position of the fluid surface, the model consist of a capillary channel of radius 50μm and a chamber. The study demonstrated that the fluid freely flown into the chamber 2mm/s without using any external mechanism.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.