A headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography–mass spectrometry (GC–MS) method was developed to determine a type of terpenoid named as cantharidin in the false blister beetles, family Oedemeridae. The experimental parameters for HS-SPME method were optimized. Six commercial fibers for HS-SPME method development were tested and the divinylbenzene/carboxene/polydimethylsiloxane fiber was selected to provide the best detection of analyzed compound. The calibration curve showed linearity in the range of 0.1–50 μg mL −1, correlation coefficient ( R 2 = 0.992), limit of detection (0.01 ng mL −1) and quantitation (0.04 ng mL −1) were obtained for the proposed method. The relative standard deviations of intra-day and inter-day assays were 7.8 and 3.4%, respectively. The recovery values, obtained after spiking the beetle samples by three concentration levels of standard solution, were higher than 87%. The results indicated the successful application of the proposed method on the analysis of cantharidin from the false blister beetles.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.