Abstract

A headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography–mass spectrometry (GC–MS) method was developed to determine a type of terpenoid named as cantharidin in the false blister beetles, family Oedemeridae. The experimental parameters for HS-SPME method were optimized. Six commercial fibers for HS-SPME method development were tested and the divinylbenzene/carboxene/polydimethylsiloxane fiber was selected to provide the best detection of analyzed compound. The calibration curve showed linearity in the range of 0.1–50 μg mL −1, correlation coefficient ( R 2 = 0.992), limit of detection (0.01 ng mL −1) and quantitation (0.04 ng mL −1) were obtained for the proposed method. The relative standard deviations of intra-day and inter-day assays were 7.8 and 3.4%, respectively. The recovery values, obtained after spiking the beetle samples by three concentration levels of standard solution, were higher than 87%. The results indicated the successful application of the proposed method on the analysis of cantharidin from the false blister beetles.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call