To find out the optimum building envelope retrofitting methods for timber dwellings in Western Hunan, China, energy efficiency retrofitting strategies of building envelope materials are optimized by an orthogonal test and energy simulation tool, DeST-h. On the premise of protecting their architectural styles, a comprehensive materials retrofitting strategy, a polyurethane foam insulation layer for the double-fir external wall envelope, reed foil for the clay insulation layer roof, using ordinary insulating glass units window material, is provided for the existing timer-structured dwellings in rural area of Western Hunan. After retrofitting, this passive strategy can achieve an energy-saving rate of 64.97%, short 4 years dynamic payback period of investment, and increase by 847h acceptable temperature hours in one year.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.