Abstract

ABSTRACTInstruments such as Beta Attenuation Monitors (BAMs) provide real-time PM2.5 mass concentration data and are now widely used in compliance monitoring networks. These devices collect the PM on a filter tape in 1-hour samples. In this work, the use of BAM filter spots for chemical speciation was investigated. Filter tapes from several sites in California were analyzed for a series of chemical species including elements, ions, organic and elemental carbon, and molecular markers. A major issue was the blank values in the filter tape. Based on blank spot analyses, it was determined that measurement of organic and elemental carbon (OC/EC) and elements were infeasible. A total of 22 BAM samples (each comprising 24 1-hour spots) from 12 sites were analyzed for ions and black carbon (BC). Additionally, 336 1-hour spots were composited to analyze for molecular markers (MM). Measurements of ions and BC at each site appear to have been underestimated likely due to volatilization losses. MM measurements in these 336 BAM filter spots suggest that organic speciation of BAM filters could be a viable method for measuring useful marker species. Statistical analysis was conducted by grouping samples into classes with mass concentrations greater and less than 80 µg m–3. Measurement of Delta-C concentrations (i.e., Delta C = BC370 nm – BC880 nm) in these two groups of samples revealed that most of the high PM2.5 concentration days PM2.5 greater than 80 µg m–3) were likely not substantially impacted by biomass combustion particles. A major portion of the samples analyzed in this work with high concentrations of PM2.5 were inorganic species such as ammonium sulfate, ammonium nitrate and other ions. Results suggested that some useful information may be derived from BAM tape analyses. However, different filter substrates and sample handling and storage practice might make a wider range of analyses possible.

Highlights

  • Fine particles with diameter less than 2.5 microns (PM2.5), contains microscopic solids or liquid droplets that cause serious health problems and ambient concentrations are regulated to protect the public health

  • We present the first reported analytical experiments conducted to explore the feasibility of using existing PM2.5 samples collected on Beta Attenuation Monitors (BAMs) filter rolls for determining the chemical composition of the collected PM2.5

  • BAM filter spot is expected to sample about 1.00 m3 of ambient air in one hour

Read more

Summary

Introduction

Fine particles with diameter less than 2.5 microns (PM2.5), contains microscopic solids or liquid droplets that cause serious health problems and ambient concentrations are regulated to protect the public health. To ensure compliance with the air quality standards, ambient PM2.5 concentrations need to be monitored. The continuous monitors used in the compliance networks in California are MetOne Model 1020 (Grants Pass, OR) Beta Attenuation Monitors (BAMs). These units measure the beta transmission through a blank piece of a filter tape, move the tape into the collection position, collect PM for an. Aerosol and Air Quality Research, 17: 14–23, 2017 hour, move the tape back to the C-14 source and measure the transmission. The difference in beta transmission between the clean and exposed filter is related to the collected PM mass. Good agreement has been shown with Federal Reference Method samples (Quok and MacDougall, 2006) and have been approved by the U.S Environmental Protection Agency as Federal Equivalent Method samplers

Methods
Results
Conclusion