Abstract
Based on the characteristics of non-uniform distribution in the fouling of hollow-fiber membrane, the non-uniform distribution of local flux and redistribution with different fiber length (0.6 m、1.2 m、1.6 m) was investigated experimentally. Experiment was conducted under the condition of operating flux 20 L/m2h (20 LMH). The results indicated that the longer fiber length was, the greater difference in local pressure and the more non-uniform the local flux distributed. Under operating mode of critical flux, the flux distribution in the length of 1.6 m membrane fiber is the most non-uniform with the fastest fouling rate. In addition, the distribution of local flux is more uniform for 0.6 m fiber under the operating flux of 16 LMH, which also slow down membrane fouling significantly. Shorter membrane fiber generally exhibited higher uniformity in the local flux distribution and slower development rate of membrane fouling.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.