Abstract
Through the analysis of 66kV arc suppression coil smoke accident in Fushun Zhong Zhai 220kV substation,scientifically pointed out that the accident was due to leave hidden trouble in the process of design and manufacture of cause.This paper introduces the working principle of arc suppression coil and use value, and cites several reasons can cause arc suppression coil accidents.This paper introduces in detail the whole process of hoisting core checks after the accident in Liao Ning Yongtai Transformer Manufacturing Co., Ltd,and carefully check the chromatography test data and the operation report before and after the accident, proveing the results of the analysis of the accident is correct.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.