Abstract

We have designed and fabricated a 3-T Magnetic Resonance Imaging (MRI) magnet system for the human brain, which was wound with Bi-2223 tape conductors. The magnet was successfully energized to 1.5 T and then up to 3.0 T. The magnet experienced more than 60 ramp-up and down processes to 1.5 T with no trouble. A magnetic field of 3.0 T (184.8 A) could be maintained for longer than 3 h without any problems. However, abnormal voltage behavior was observed during the ramp down for the third trial to 3.0 T, and the temperature rapidly increased with a ramping rate of 1.7 K/min. To investigate the cause, we opened the cryostat and inspected the inside of the magnet. In addition, we have analyzed the details of this event using the recorded current, voltage, and temperature data. The purpose of this paper is to report the investigation of this abnormal event in the magnet.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.