Abstract

Twelve healthy term infants were examined at the median ages of 2 1/2 and 26 hours. Their alveolar ventilation, efficiency of ventilation, functional residual capacity, and lung nitrogen elimination patterns were studied by means of a computerised nitrogen wash out method. The results showed that alveolar ventilation and functional residual capacity increased over the period studied. At the same time effective dead space decreased leaving minute ventilation unchanged. Distribution of ventilation did not change.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.