Abstract

A Polyvac E980 (Hilger Analytical) photoelectric vacuum optical emission spectrometer has been modified with a multichannel analyzer of emission spectra (MAES). The line of argon supply to the spark stand has been completely renewed. A precision mass flow controller with a microprocessor control unit has been installed to adjust the argon supply for different operation modes and fix the current values with the possibility of saving data for each spectrum. The microprocessor control unit coordinates the operation of the control lines and interrupts the operation of the spark generator when the stand is open or argon is absent. The modified vacuum spark spectrometer, originally designed for the analysis of iron-based alloys, has become suitable for determining the composition of non-ferrous alloys. Analytical programs have been developed for the rapid spectral analysis of AK12M2 and AK9ch aluminum alloys. The main methodological difficulty of the analysis is attributed to the necessity of monitoring high concentrations of silicon, copper, and iron along with the content of calcium impurity in the same sample. Calcium has a negative effect on the quality of castings, thus making the possibility of Ca determination an important motivation for the modification. After the preparatory work and the construction of calibration curves, the short-term and long-term repeatability of the results of spectral analysis of standard samples of aluminum alloys has been studied on the modified spectrometer. The results completely meet the standard requirements for determining the composition of aluminum alloys.

Highlights

  • Ïðåäñòàâëåíû ðåçóëüòàòû ìîäåðíèçàöèè âàêóóìíîãî àòîìíî-ýìèññèîííîãî ñïåêòðîìåòðà Polyvac Å980 (Hilger Analytical, Âåëèêîáðèòàíèÿ) ìíîãîêàíàëüíûì àíàëèçàòîðîì ýìèññèîííûõ ñïåêòðîâ ÌÀÝÑ: áûëà ïîëíîñòüþ îáíîâëåíà ëèíèÿ ïîäà÷è àðãîíà â èñêðîâîé øòàòèâ è óñòàíîâëåí ïðåöèçèîííûé ðåãóëÿòîð ìàññîâîãî ðàñõîäà ñ áëîêîì ìèêðîïðîöåññîðíîãî óïðàâëåíèÿ äëÿ ðåãóëèðîâàíèÿ ïîäà÷è àðãîíà

  • Ïîñëå ïðîâåäåíèÿ âñåõ ïîäãîòîâèòåëüíûõ ðàáîò è ïîñòðîåíèÿ ãðàäóèðîâî÷íûõ ãðàôèêîâ èññëåäîâàëè êðàòêîâðåìåííóþ è äîëãîâðåìåííóþ ïîâòîðÿåìîñòü ðåçóëüòàòîâ àíàëèçà ñòàíäàðòíûõ îáðàçöîâ àëþìèíèåâûõ ñïëàâîâ ñ èñïîëüçîâàíèåì ìîäåðíèçèðîâàííîãî ñïåêòðîìåòðà

  • A Polyvac E980 (Hilger Analytical) photoelectric vacuum optical emission spectrometer has been modified with a multichannel analyzer of emission spectra (MAES)

Read more

Summary

Îáñóæäåíèå ðåçóëüòàòîâ

Îöåíêó ïîâòîðÿåìîñòè ïðîâîäèëè â ñîîòâåòñòâèè ñ òðåáîâàíèÿìè ÃÎÑÒ 7728–81 [16]: ðàñõîæäåíèå ìåæäó ðåçóëüòàòàìè ïàðàëëåëüíûõ îïðåäåëåíèé ýëåìåíòà íå äîëæíî ïðåâûøàòü äîïóñêàåìîãî ðàñõîæäåíèÿ d. Çíàêîì (*) îòìå÷åíû ðåçóëüòàòû àíàëèçà, äëÿ êîòîðûõ ðàçìàõ ìåæäó ìàêñèìàëüíûì è ìèíèìàëüíûì çíà÷åíèÿìè ìàñ-. Ðåçóëüòàòû ñïåêòðàëüíîãî àíàëèçà (% ìàññ.) îáðàçöà ÑÎ 1 27 ñïëàâà ÀÊ12Ì2, ïîëó÷åííûå â òå÷åíèå 10 ìèí íåïðåðûâíîé ðàáîòû ñïåêòðîìåòðà Polyvac E980 ñ àíàëèçàòîðîì ÌÀÝÑ

Âðåìÿ èçìåðåíèÿ
Îïðåäåëÿåìûé ýëåìåíò
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.