Abstract

Acoustic leak control systems (for instance, SAKT) are used at present for controlling leak tightness of equipment and pipelines, as well as for detecting in timely manner coolant leaks from the primary cooling circuit of nuclear reactor installations (NRI) during operation of power unit on different power levels in the modes of normal operation and during disturbances of normal operation. Time averaged dispersion of acoustic signal is used as the main diagnostic indicator for detecting leaks in these systems. Sensitivity of this indicator is determined by the exceedance by the signal of the preset threshold value which is defined in accordance with the background. Here, background values of acoustic signal depend on the operational modes of the equipment and do not allow in many cases determining coolant leak during early stages of leak development. New approach to the formation of diagnostic indicators for detecting loss of sealing in the circuit during early stage of development of coolant leak is suggested. Methodology for obtaining diagnostic indicators is based on the processing in different frequency bands of acoustic signal accompanying coolant leakage from the pipeline using the method of principal components. Efficiency of the developed methodology of coolant leak detection is illustrated by processing acoustic signals for experimental facility modeling coolant leakage in case of loss of sealing of the circuit. Even in the presence of significant acoustic background sensitivity of the method allows detecting leaks with significantly lower flow rates (up to five times smaller) than the conventional processing of acoustic signals. Implementation of the developed methodology will not require significant expenditures for upgrading already existing leak control systems operated at present on different NPPs.

Highlights

  • Acoustic leak control systems (SAKT in Russian abbreviation) are used at present for controlling leak tightness of equipment and pipelines, as well as for detecting in timely manner coolant leaks from the primary cooling circuit of nuclear reactor installations (NRI) during operation of power unit on different power levels in the modes of normal operation and during disturbances of normal operation (Arkadov et al 2010, Weiss et al 1988, Basseville 1988, Herbert 1984)

  • Time averaged dispersion of acoustic signal is used as the main diagnostic indicator for detecting leaks in this system

  • Background values of acoustic signal depend on the operational modes of the equipment and do not allow in many cases determining coolant leak during early stages of leak development

Read more

Summary

Research Article

Analysis of acoustic leak signals for enhancing sensitivity of control due to the creation of effective diagnostic indicators*. Nuclear Energy and Technology 4(2): 141–147. https://doi.org/10.3897/ nucet.4.30775

Introduction
Experimental facility
Traditional approach
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.