Abstract

To increase the efficiency of designing systems intended for monitoring surface cracks in aluminum structures during their working life, we have analyzed a two-dimensional symmetric problem on uniaxial extension of an Al-polyimide-Cu layered structure with ideal adhesion between layers and a model crack in the aluminum base. The problem has been first solved for a sample with the crack modeled by a zero-thickness notch using the ANSYS engineering simulation program package. It is shown that this setting of the problem can lead to inadequate results as manifested, in particular, by significantly overstated mechanical stresses in aluminum in the region of crack emergence on the surface. In order to eliminate this difficulty, we propose to use the structure with a model defect in the form of a notch of nonzero thickness in the initial unstressed state of the structure. Recommendations for selecting the thickness of a notch used in the model structure are given.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.