Abstract

A study of heat transfer in a two-pass internal cooling passage of gas turbine airfoils is presented. Heat transfer measurements were performed with a transient technique using thermochromic liquid crystals. Flow temperature measurements along the channels are used to evaluate the heat transfer distribution. Thereby two methods are applied. The first uses the measured temperature histories directly and applies the superposition method for data evaluation. The second method analyses first the fluid temperature data using a simplified model and relates them to the average flow temperature at a given location. The results of both methods are compared.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.