The aim of the study was to determine the parameters of a detonator generating a self-centring detonation wave, based on experimental and theoretical analysis. The methods for manufacturing selfcentring detonation wave generators available in literature were reviewed and a detonator comprised of two explosives was proposed. The detonator geometry was analysed for its ability to centre the detonation wave. A physical detonator model was created and the detonation wave front downstream of the detonator, analysed and the detonator’s capability to compensate an off-centre detonation initiation, evaluated. The wave fronts were recorded using pulsed x-ray radiography. The study showed that the proposed detonator provides a symmetrical initiation of the main charge for the initiation point (location) offset, lower than the assumed maximum offset.