Abstract

The reduction of energy demand and the indoor air quality associated with energy demand are the main goals of thermal buildings. This work is devoted to the study of the effect of a reactive porous separation on the ventilation (cooling) and depollution capacity in a rectangular room ventilated by air displacement. The model is considered as a cavity heated on its right verticle wall and thermally isolated by the other three walls. A porous separation divides the room into two compartments. The system of equations was solved using the Lattice Boltzmann method with multiple relaxation times. The extended Darcy Brinkman-Forchheimer model was used to simulate the porous material. An additional linear term is added to the standard transport equations (material diffusion) to account for reaction effects, this term was derived from Arrhenius' law. Over a wide range of Richardson and Darcy numbers, the results of the computations show the influence of these parameters on the flow structure, making it possible to categorize the different convection phenomena (natural, forced and mixed). The most important point to note is that the addition of reaction (fixing reaction) improves indoor air quality and can achieve a 55 % reduction in air renewal time, thus saving on energy costs. However, this reactif effect has no influence on the thermal efficiency of the proposed model.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call