Abstract

In moving toward ITER operation, the detailed analysis of fault conditions for the magnets becomes of increasing importance, to verify that the magnet protection system can safely manage them without any damage to the magnets. A “protected” loss of flow accident in the ITER toroidal field coils, detected by the coil flow meters and managed by the central interlock system, is investigated here using the validated thermal–hydraulic code 4C. We simulate the entire sequence of events that is foreseen to protect the magnet, aiming at verifying the impact on the magnet. The loss of flow accident consequences are investigated in terms of both the temperature margin in the winding pack and of the needed recooling time, which will affect the availability of the machine. It turns out that, for an “accelerated” discharge (i.e., a linear ramp-down) of the magnet current lasting less than 30 min, no quench should occur, while the corresponding recooling time should not exceed 1 h. During the transient, ∼10% of the He mass in the coil is vented to the quench tank due to the opening of the safety valves, and requires recooling.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.