Abstract

This paper is introducing a new method of operation for a series resonant converter, with intended application in megawatt high-voltage dc wind turbines. Compared to a frequency controlled series resonant converter operated in subresonant mode, the method (entitled pulse removal technique) allows the design of the medium frequency transformer for highest switching frequency, while being operated at lower frequency without saturation. The main focus of this paper is to identify and analyze the operating modes of the converter with pulse removal technique. With the use of variable frequency and variable phase displacement in subresonant mode, the new method of operation promises transformer size reduction and facilitates soft-switching transition of the insulated gate bipolar transistors (IGBTs) and line frequency diodes on rectifier side. Four modes of operation are identified, while equations for output power, voltage, and current stress are identified. Experimental results are concluded on a 1 kW, 250 V/500 V prototype.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call