Abstract

The LLC resonant converter has a critical problem that the output voltage cannot be regulated at very light load condition, although switching frequency is widely changed. This letter proposes time domain analysis considering parasitic components at very light load condition. Based on the proposed analysis, the essential reason of the regulation problem of the LLC resonant converter at very light load condition is described and the clear solution is suggested. To confirm the validity of the proposed analysis, the experimental results with 200W prototype is presented.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.