Abstract

A charge pump high power factor converter cell is first derived, and its unity power factor condition is then reviewed. A single stage high power factor electronic ballast using the charge pump concept is then analyzed. Design criteria are derived to optimize the electronic ballast based on the steady state analysis. Constant lamp power operations associated with its control are also discussed. Large signal simulation and experimental results verify the theoretical analysis. It is shown that the designed electronic ballast has 0.995 power factor and 5% total harmonic distortion with lamp power variation within /spl plusmn/15% when the line input voltage changes /spl plusmn/10%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.