Abstract

This paper presents a detail research on a vibration high fault after overhaul occurred on a generator. During the overhaul, the generator rotor is returned to factory for processing and replaces section across the line of the generator excitation end. The gas turbine unit vibrates high in the idle 3000 r·min−1 and full load. The large vibration of the generator is mainly caused by the following two factors:the imbalance in the overhanging end of the generator rotor and the electrical fault in the generator itself. The unbalanced amount of generator overhang was successfully eliminated by dynamic balance test. The electrical fault of generator itself needs to be returned to the factory to handle.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.