Abstract
The water level of NO.2 high pressure heater rised when the 150MW turbogenerator set of a power plant operated normally, it was unassembled and checked. After the high pressure heater was put into operation, the water level of the boiler drum droped. After the standby electric pump was started and the electric load was reduced, the water level of the boiler drum still droped, resulting in the boiler feed water flow reduced to the protection action and the unit shutdown. Through inspection, it was found that the connecting rod pin of the manual valve at the outlet of the high-pressure heater was broken, which maked the manual valve at the outlet not fully open and lead to low water flow rate at the water side of the high-pressure heater.After the corresponding improvement and optimization measures were taken, the unit can be restarted and run normally .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Materials Science and Engineering
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.